Bidirectional Alignment of Glottal Pulse Length Sequences for the Evaluation of Pitch Detection Algorithms

dc.contributor.authorFerrer-Riesgo, Carlos A.
dc.contributor.authorRodriguez-Guillen, Reinier
dc.contributor.authorNöth, Elmar
dc.contributor.departmentUniversidad Central "Marta Abreu" de Las Villas. Departamento de Telecomunicaciones y Electronicaen_US
dc.contributor.departmentUniversidad Central "Marta Abreu" de Las Villas. Laboratorio de PDSI adjunto a Centro de Estudios de la Informaticaen_US
dc.contributor.departmentFriedrich Alexander University Erlangen-Nuembergen_US
dc.coverage.spatialHabana-Cubaen_US
dc.date.accessioned2024-02-19T15:38:37Z
dc.date.available2024-02-19T15:38:37Z
dc.date.issued2019-10-28
dc.description.abstractThis paper describes a problem in a reported Dynamic Time Warping (DTW) alignment procedure to compare the reference and detected glottal pulse length sequences, oriented to compare the evaluation of Pitch Detection Algorithms (PDAs) in pathological voices. The problem in the existing alignment method tends to overestimate the failure of the PDA, by aligning only the detected to the reference sequence. A solution is presented, which performs a bidirectional alignment reducing the differences present in the definitive comparison. The proposal is evaluated in both synthetic and real voice signals, by running three well-known PDAs, and the magnitude of the error reduction along with comments on the possible factors influencing its value, are given. The alignment variant introduced in this paper allows to perform a fairer comparison of the PDAs performances.en_US
dc.identifier.citationFERRER, Carlos A.; GUILLÉN, Reinier Rodríguez; NÖTH, Elmar. Bidirectional Alignment of Glottal Pulse Length Sequences for the Evaluation of Pitch Detection Algorithms. En Iberoamerican Congress on Pattern Recognition. Springer, Cham, 2019. p. 707-716.en_US
dc.identifier.doihttps://doi.org/10.1007/978-3-030-33904-3_67en_US
dc.identifier.isbn978-3-030-33904-3en_US
dc.identifier.urihttps://dspace.uclv.edu.cu/handle/123456789/14215
dc.language.isoen_USen_US
dc.relation.conference24th Iberoamerican Congress on Pattern Recognition (CIARP 2019)en_US
dc.subjectDynamic Time Warping - Pitch Detection Algorithms - Jitter - Alignmenten_US
dc.titleBidirectional Alignment of Glottal Pulse Length Sequences for the Evaluation of Pitch Detection Algorithmsen_US
dc.typeProceedingsen_US

Archivos

Bloque original
Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
491378_1_En_67_Chapter_Author (CIARP).pdf
Tamaño:
903.16 KB
Formato:
Adobe Portable Document Format
Bloque de licencias
Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
license.txt
Tamaño:
3.33 KB
Formato:
Item-specific license agreed upon to submission
Descripción: