Optimización de la calidad de imagen en radiografía digital de la mama vs. dosis a la paciente

dc.contributor.authorBernardo, Almeida António
dc.contributor.authorPérez Díaz, Marlen
dc.contributor.authorEchevarría Torres, Waldo Jose
dc.contributor.authorDíaz Amador, Roberto
dc.contributor.departmentUniversidad Central "Marta Abreu" de Las Villas. Departamento de Físicaen_US
dc.contributor.departmentUniversidad Central "Marta Abreu" de Las Villas. Departamento de Físicaen_US
dc.contributor.departmentUniversidad Central "Marta Abreu" de Las Villas. Departamento de Físicaen_US
dc.contributor.departmentUniversidad Central "Marta Abreu" de las Villas. Departamento de Electrónica y Telecomunicacionesen_US
dc.coverage.spatialLa Habanaen_US
dc.date.accessioned2021-01-07T21:45:45Z
dc.date.available2021-01-07T21:45:45Z
dc.date.issued2020
dc.description.abstractA ́un no existe un conocimiento profundo de la calidad de imagenrespecto a la dosis, que se puede obtener empleando la tecnolog ́ıa“Computed Radiography” (CR). Hacia este objetivo se enfoc ́o elpresente trabajo. Se analizan im ́agenes de mamograf ́ıa digitalobtenidas de un maniqu ́ı antropom ́orfico. Se vari ́o la corrienteque alimenta al tubo de rayos X y el tiempo de adquisici ́on de laimagen y la energ ́ıa del haz de rayos X y se analiz ́o la influenciade esta variaci ́on sobre la dosis media glandular y la calidadde imagen. Para esto se emplearon las medidas matem ́aticasrelaci ́on se ̃nal-ruido, contraste imagen, relaci ́on contraste-ruido, ́ındice de similitud estructural, distancia espectral y error mediocuadr ́atico y se estimaron las dosis a partir de mediciones conuna c ́amara de ionizaci ́on. Tambi ́en se analiz ́o la calidad deimagen subjetivamente utilizando criterio de expertos. Se obtuvoun protocolo optimizado que reduce la dosis media glandularsignificativamente manteniendo buena la calidad de imagen.en_US
dc.description.abstractThere is still not in-depth knowledge of image quality with respect to the dose that can be obtained using “Computed Radiography” (CR). Toward this aim the present work was focused on. Digital mammography images obtained from an anthropomorphic phantom were analyzed. The current of the X-ray tube and the acquisition time as well as the energy of the X-ray beam were varied and the influence of these variations on the mean glandular dose and image quality were analyzed. Mathematical metrics like signal-to-noise-ratio, image contrast, contrast-to-noise ratio, structural similarity index, spectral distance and mean squared error were used to grade image quality. Subjective image quality analysis, using the criteria of expert observers, was also included and the doses were estimated from measures done with an ionization chamber. An optimized protocol was obtained which reduced the mean glandular dose significantly while a good image quality was maintaineden_US
dc.description.sponsorshipSociedad Cubana de Física y Universidad de La Habanaen_US
dc.identifier.issn0253-9268en_US
dc.identifier.urihttps://dspace.uclv.edu.cu/handle/123456789/12659
dc.language.isoen_USen_US
dc.relation.journalRevista Cubana de Física (En línea)en_US
dc.rightsEste documento es Propiedad Patrimonial de la Universidad de La Habana y se socializa en este Repositorio gracias a la política de acceso abierto de la Revista Cubana de Físicaen_US
dc.rights.holderUniversidad de La Habanaen_US
dc.source.endpageE20en_US
dc.source.initialpageE17en_US
dc.source.issue1Een_US
dc.source.volume35en_US
dc.subjectDigital Mammographyen_US
dc.subjectImage Qualityen_US
dc.subjectMean Glandular Doseen_US
dc.subjectOptimizationen_US
dc.subject.otherMamografía Digitalen_US
dc.subject.otherCalidad de la Imagenen_US
dc.subject.otherDosis Glandular Mediaen_US
dc.subject.otherOptimizaciónen_US
dc.titleOptimización de la calidad de imagen en radiografía digital de la mama vs. dosis a la pacienteen_US
dc.title.alternativeImage quality optimization in breast digital radiography vs. patient doseen_US
dc.typeArticleen_US
dc.type.article1en_US

Archivos

Bloque original
Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
RCF_35_E17.pdf
Tamaño:
269.14 KB
Formato:
Adobe Portable Document Format
Bloque de licencias
Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
license.txt
Tamaño:
3.33 KB
Formato:
Item-specific license agreed upon to submission
Descripción: