Implementar un proceder para la obtención de los reactivos hemoclasificadores policlonales ABO en el banco de sangre provincial de Cienfuegos

dc.contributor.advisorFernadez Feros, Blanca
dc.contributor.advisorSaucedo Hernández, Yanelis
dc.contributor.advisorMenendez Barrios, Ariel
dc.contributor.advisorSanches Frenes, Pedro
dc.contributor.authorTorres González, Lilian
dc.coverage.spatial1016432en_US
dc.date.accessioned2015-10-15T19:29:17Z
dc.date.available2015-10-15T19:29:17Z
dc.date.issued2006-06-25
dc.description.abstractCon el objetivo de elevar la calidad de los reactivos hemoclasificadores policlonales ABO, se realizó una amplia revisión bibliográfica para implementar un proceder que permitiera la manufactura del producto con el cumplimiento de las Buenas Prácticas de Laboratorio Clínico, y las Buenas Prácticas de Producción en el departamento de Producción del Banco de Sangre Provincial de Cienfuegos. Se diseñaron y elaboraron los documentos que forman parte del sistema de documentación, entre ellos: el procedimiento normalizado de operaciones, los documentos para la recolección de los datos, así como los registros de trazabilidad, modelos de solicitud de ensayos microbiológico y funcional y el protocolo de liberación. En el departamento de Aseguramiento de la Calidad se introdujeron los ensayos funcionales establecidos por el CEDMED para la evaluación de los reactivos hemoclasificadores policlonales y monoclonales del sistema de grupos sanguíneos humanos ABO1 , con el propósito de determinar de la calidad del lote del reactivo anti-AB policlonal . Se entrenó al personal responsable de esta actividad en el uso de estos métodos de evaluación del producto terminado. Los resultados de los ensayos funcionales fueron satisfactorios debido a que cumple con los requisitos de potencia, avidez y especificidad. Además se evaluó en paralelo con el reactivo anti-AB de origen monoclonal producido por Centics Diagnóstico en cuanto a potencia, avidez e intensidad de la reacción en los cuales demostró ser eficaz como reactivo hemoclasificador.en_US
dc.description.abstractWith the objective of rising up the quality of the serums blood grouping reagent ABO, It was carried out a wide bibliographic checking, to put in practice a new procedure which permits the product is manufacturing , taking into consideration a good practice of clinic laboratory and a good manufacturing practice at the Production Department from the Blood Banks at Cienfuegos Province. There were designed and produced the documents which take part of the documentation system between them. The Normalized Procedure for Operation, the documents for the recollection of data, as well as the registers of trace ability ,the analysis request models, microbiological and functional. The were introduce, functional essays at the quality assurance department which were establish by CEDMED, for the evaluation of the Policlonal and Monoclonal human blood grouping reagent system ABO. Which the objective of determined the quality of the anti-AB policlonal reactive lot. The responsible persons for this activity has been well trained for using this evaluative methods of defined products. The functional essays results were satisfactory due to the potent, avid and specific requirement were not violated. Besided that it was evaluated parallel with the anti-AB reactive from monoclonal origin produced by Centics Diagnósticos taking into consideration. The potent, avid and intensity of the reaction in which it showed to be very efficient as an blood grouping reagent.en_US
dc.description.sponsorshipFacultad de Química y Farmacia. Departamento de Farmaciaen_US
dc.description.statusnon-publisheden_US
dc.identifier.urihttps://dspace.uclv.edu.cu/handle/123456789/2396
dc.language.isoesen_US
dc.publisherUniversidad Central "Marta Abreu" de las Villasen_US
dc.rightsEste documento es Propiedad Patrimonial de la Universidad Central ¨Marta Abreu¨de Las Villas. El autor o autores conservan los derechos morales que como tal le son reconocidos por la Legislación vigente sobre Derecho de Autor. Los distintos Usuarios podrán copiar, distribuir, comunicar públicamente la obra y hacer obras derivadas; bajo las condiciones siguientes: 1. Reconocer y citar al autor original. 2. No utilizar la obra con fines comerciales. 3. No realizar modificación alguna a la obra. 4. Compartir aquellos productos resultado del uso de la obra bajo la misma licencia de esta. 5. Los Usuarios pueden reutilizar los metadatos en cualquier medio sin autorización previa, siempre que los propósitos de su utilización sean sin ánimo de lucro y se provea el Identificador OAI, un enlace al registro de metadatos original, o se haga referencia al repositorio de donde han sido extraídos.en_US
dc.subjectBuenas Prácticas de Laboratorio Clínicoen_US
dc.subjectBanco de Sangre Provincialen_US
dc.subjectCienfuegosen_US
dc.subjectCEDMEDen_US
dc.titleImplementar un proceder para la obtención de los reactivos hemoclasificadores policlonales ABO en el banco de sangre provincial de Cienfuegosen_US
dc.typeThesisen_US
dc.type.thesisbacheloren_US

Archivos

Bloque original
Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
Q06020.pdf
Tamaño:
556.67 KB
Formato:
Adobe Portable Document Format
Bloque de licencias
Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
license.txt
Tamaño:
3.33 KB
Formato:
Item-specific license agreed upon to submission
Descripción: